Products

TOX/AOX/EOX

Laboratory

Process

TOX/AOX/EOX/POX/TX/TS/TN
Mitsubishi Model TOX-100

Measure TOX / AOX / EOX / POX / TX / TS & TN concentrations from ppb to low % levels.

Fast
Typical analysis times are under 7 minutes.
Flexible
Optional sulfur cell and nitrogen detector combine with solid, liquid and gaseous sampling systems to handle virtually any analytical application.
Reliable
TOX/AOX/EOX/POX/TX by EPA and Standard Methods approved oxidative combustion microcoulometry has a proven record of performance and reliability. Measure total sulfur and nitrogen by accepted ASTM methodology.
Powerful
Determine TOX / AOX / EOX / POX / TX / TS & TN all with one instrument.

    TOX Brochure

The TOX-100's modular design provides customers a broad range of customized configurations, unique to their application, while at the same time simplifying any future system changes or upgrades. The data handling and acquisition software operates under a variety of platforms, including MS Windows® 95/98, MS Windows® NT, MS Windows® Millennium Edition and MS Windows® XP. The built in MS Access® database and MS Crystal® Report Writer makes data presentation and retrieval a breeze.

    REGULATORY COMPLIANCE METHODS INCLUDE

  • EPA SW-846 Method 9020B for TOX (Total Organic Halides)
  • EPA SW-846 Method 9021 for POX (Purgeable Organic Halides)
  • EPA SW-846 Method 9023 for EOX (Extractable Organic Halides)
  • EPA SW-846 Method 9076 for TX (Total Halides)
  • EPA Method 450.1 for TOX (Total Organic Halides)
  • EPA Method 1650B "Cluster Rule" for AOX (Absorbable Organic Halides)
  • Standard Methods 5320 (Total Organic Halides) for EPA's "Information Collection Rule (ICR) for Drinking Water"


    APPLICATIONS

  • Drinking Water
  • Surface, Ground and Wastewater
  • Landfill Monitoring
  • Hazardous and Solid Waste Characterization
  • Waste Oils and Solvents
  • Paper & Pulp Mill Effluent
  • Coal and more...

    ACCESSORIES

  • AOX Autosampler Model AutoAOX-100 (40 position AC Column Carousel)
  • POX Sparger Model POX-100 (100 mL sample volume, 0°-60°C Heating Temperature)
  • 3 & 5-Channel Adsorption Modules Model TXA-023B and TXA-02B (10 - 100 mL Sample Volume)
  • Liquid Autosampler Model ASC-150L (25, 50 & 100 ul Syringes Available)
  • Solid Autosampler Model ASC-120S (Maximum Capacity 500 mg)
  • Syringe Inlet System Model CRI-100 (25, 50, 250, 1000 and 2500 ul Syringes Available)
  • LPG & Gas Sampling System (Standard Sample Loop:20 ul-LPG & 20 mL-Gas)